As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT CRACKED BS 312-328 LBL 45 WL 208 / REMOVED CRACKED FLOOR SUPPORT PER SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-05-0G-0 AND DWG 141A5410. INSTALLED NEW FLOOR SUPPORT BS312-328 LBL45 WL208 PER SRM 51-40-02-G0-0 AND DWG 141A5400.