What was found
#5 FLAP TRACK AFT FAIRING ACCESS PANEL #194BR DELAMINATED AND CRACKED. / REMOVED AND REPLACED PER AMM 53-51-21. PERFORMED ELECTRICAL BOND INPECTION AND RESISTANCE CHECK PER AMM 53-51-21. INSPECTION CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
#5 FLAP TRACK AFT FAIRING ACCESS PANEL #194BR DELAMINATED AND CRACKED. / REMOVED AND REPLACED PER AMM 53-51-21. PERFORMED ELECTRICAL BOND INPECTION AND RESISTANCE CHECK PER AMM 53-51-21. INSPECTION CHECKS GOOD.