As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PASSENGER COMPARTMENT FLOOR STRUCTURE; STA 1016 +13 WL 208 LBL 3 STRAP HAS CORROSION / REMOVED DAMAGED STRAP AT 1016+13 WL 208 LBL 3 AND INSTALLED NEW STRAP ITEM 147A5620U3 P.O. 725693 PER SRM 51-40-02 AND BOEING DWG 147A5600 REV H AND BOEING DWG 147A5730 REV: A TRM 57373U 1-20-19 DAMAGD STRAP FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN SRM