What was found
***CORROSION*** AFT CARGO BAY FLOOR SPLICE SUPPORT AT STA 887 HAS MULTIPLE SPOTS OF CORROSION ON UPPER SURFACE FROM RBL 22 TO LBL 6 / REMOVED CORROSION AFT CARGO BAY FLOOR SPLICE SUPPORT STA 887 RBL 22 TO LBL 6 NO SRM ENTRYS AVAILABLE; REPLACED WITH NEW PART PER SRM 51-10-02-0G-0. LOCATED AND DRILLED NEW SPLICE SUPPORT IAW SRM 51-40-05-0G-0; DWG# 146A9401. P.O.# 725077 RECEIPT# 5078496 PN# 146A9401U21 INSTALLED NUTPLATES IAW DWG# 146A9401 REV A AND SRM 51-40-02-0G-0. PART TO BE INSTALLED ON JPANEL-141-CLOSE CARD