What was found
A22-51; AFT PIT STA 865; LBL10; OTBD SIDE OF VERTICAL SUPPORT STANSION; FLOOR SUPPORT SPLICE SUPPORT ANGLE; CRACKED; MRK'D. SECONDARY STRUCTURE / [01] REMOVED AFT CARGO BAY FLOOR SPLICE SUPPORT ANGLE AT STA 865 LBL10 IAW SRM 51-40-02-0G-0;[02] VERIFIED NEW SUPPORT ANGLE TO BE MPN: 149A8109U114 ATAG: A105630 IAW B737-800 DWG: 149A8102 REV: A;[03] LOCATED AND DRILLED NEW SUPPORT ANGLE IAW SRM 51-40-05-0G-0 AND B737-800 DWG: 149A8102 REV: A;[04] VERIFIED STEPS 1; 2 AND 3;[05] OK TO INSTALL;[06] INSTALLED NEW SUPPORT ANGLE IAW SRM 51-40-02-0G-0 AND DWG: 149A8102 REV: A;[07] REMOVED AND REPLACED AFT CARGO BAY FLOOR SPLICE SUPPORT ANGLE AT STA 865 LBL10 IAW SRM 51-40-02-0G-0 AND B737-800 DWG: 149A8102 REV: A;[08] VERIFIED TASK COMPLETE<BR><BR>AUDIT COMPLETE