What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE; LOWER SILL SUPPORT STRAP STA 780 TO STA 800 RBL 19 HAS CORROSION. / REMOVED CORROSION PER SRM 51-10-02-0G-0. BLEND DIMENSIONS 1' X 3' WITH MAX DEPTH OF .025' FROM ORIGINAL .162 WITH .142' REMAINING. BLEND FOUND TO BE OUT OF LIMITS PER SRM 53-60-15-1A. REMOVED AND REPLACDED LOWER SILL SUPPORT STRAP STA 790 TO STA 775 PER DWG 146A8920 REV A AND SRM 51-40-02-0G-0 ATAG # R10122