What was found
AFT GALLEY DOOR CUTOUT; LWR SILL PLATE; INBD CHORD CORRODED FROM BS 951 TO BS 993. / BLENDED AND REMOVED CORROSION ON AFT GALLEY DOOR CUTOUT LWR SILL INBD CHORD BETWEEN STA 951 TO 993. ORG 'T' .080' REMOVED .023' MATERIAL WITH .057' REMAINING OUT OF LIMITS IAW SRM 53-70-15-1A-1. LOCATED; DRILLED AND INSTALLED NEW INBD CHORD IAW DWG 147A850 TAG#WN3711