What was found
***CORROSION*** FWD ENTRY DOOR CUT OUT; STA 312 +7 TO STA 344 MIDDLE SCUFF PLATE SUPPORT ANGLE HAS CORROSION ( 9 LOCATIONS) / CORROSION AT FWD ENTRY DOOR CUT OUT STA 312 + 7 TO STA 344 MIDDLE SCUFF PLATE SUPPORT ANGLE WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1. REMOVED SUPPORT ANGLE IAW SRM 51-40-02-0G-0. LOCATED; DRILLED AND INSTALLED NEW SUPPORT ANGLE P.O.# 721902 IAW SRM 51-40-02-0G-0; 51-40-05-0G-0. AND DWG 141A8110. 92058 02/05/19