What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS947 LBL7 TO RBL17. / [01] EVALUATED CORROSION ON BULKHEAD SUPPORT BS 947 LBL 7 TO RBL 17 WL 179; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION ENTRY 1.;[03] LOCATED; DRILLED; AND DEBURRED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS947 LBL10 TO RBL23 PER SRM 51-40-05-0G-0 AND DWG 149A8117 AND DWG 149A8110;[04] VERIFIED CORRECTIVE ACTION #3;[05] OK TO INSTALL;[06] VERIFIED CORRECTIVE ACTION #5<BR>OK TO INSTALL GIVEN;[07] INSTALLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947 LBL 7 TO RBL 17 IAW SRM 51-40-02-0G-0; DWG 149A8117 AND DWG 149A8110;[08] VERIFIED CORRECTIVE ACTION ITEM 7;[09] VERIFIED CORRECTIVE ACTION ITEM 7;[10] CORRECTED MEASUREMENT TABLE