What was found
CRACKED INTERCOSTAL STA 344-360; LBL 11; WL 208. / [01] REMOVED DAMAGED INTERCOSTAL STA 344-360; LBL 11; WL 200-208 PER SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED NEW INTERCOSTAL STA 344-360; LBL 11; WL 208 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG#141A5400; REV B. OK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION 1 AND 2;[04] INSTALLED NEW INTERCOSTAL STA 344-360; LBL 11; WL 208 PER SRM 51-40-02-0G-0; SRM 51-40-03-0G-0; DWG#141A5400; REV B;;[05] VERIFIED CORRECTIVE ACTION #4;[06] VERIFIED TASK COMPLETE