What was found
FWD CARGO COMP. CUPSTRIP FROM STA 500 TRHU 500 R/H SIDE ;RBL 24' STR. 25R WITH CORROSION / [01] REMOVED CORROSION AT CUPSTRIP STA 500 R/H RBL 24''.PER B 737-700 SRM 51-10-02-0G-0.MEASURED REWORKED AREA ;FOUND OUT OF LIMITS.ORIGINAL THICKNESS 0.040'' MATERIAL REMOVED 0.025'' MATERIAL REMAINING 0.015''.INSTRUMENT USED MICROMETER I/D 165543 DUE DATE 01-SEP-22.;[02] VERIFIED STEP #1.;[03] THIS STEP IS FOR CORRECTION ON THE ITEM DESCRIPTION NO CUPSTRIP SHOULD BE CAPSTRIP;[04] THIS STEP IS FOR CORRECTION ON THE ITEM DESCRIPTION;IS FROM STA 500 THRU 500D;[05] REPLACED FWD CARGO COMP. CAPSTRIP R/H SIDE FROM STA 500 THRU 500D RBL 24' STR.25R REF. 51-10-02-0G-0.CAPSTRIP WILL INSTALLED ON CARD #TTG8Q004ATSM;[06] VERIFIED STEP 5.