What was found
***CORROSION*** FWD CARGO BAY AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS500D LBL22 TO RBL25 WL156. MARKED / FWD CARGO BAY AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT BS 500D.; LBL 22 TO RBL 25; WL 156 OUT OF LIMITS IAW SRM 53-00-53-1A-2. REPAIR BY REPLACEMENT IAW SRM 51-10-02-0-G0. REMOVED DAMAGED FROM SUPPORT ANGLE IAW SRM 51-40-02-0-G0. INSTALLED A NEW FLOOR SUPPORT ANGLE IAW SRM 51-40-05-0G-0 AND SRM 51-40-02-0G-0 AND DWG 143A9481 SH 8; REV A AND DWG 143A7902