What was found
PANEL 193B HAS DELAMINATION; CRACKING AND EVIDENCE OF FASTENERS PULLING THROUGH ON INNER SURFACE OF PANEL AT FASTENER LOCATION 1; 2; 5; 34; 36; AND 38 / R&R PANEL 193B PER AMM 53-51-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PANEL 193B HAS DELAMINATION; CRACKING AND EVIDENCE OF FASTENERS PULLING THROUGH ON INNER SURFACE OF PANEL AT FASTENER LOCATION 1; 2; 5; 34; 36; AND 38 / R&R PANEL 193B PER AMM 53-51-21.