What was found
193 B. PANEL EROSION OF CORNER LOCATION (8) (MARKED). ALOO HAS HOLE IN PANEL SURFACE NOT CONTINUING THRU JUST FWD OF FASTENER 34. HOLE IS APPROX .125 IN DIAMETER AND HAS LOCALIZED DELAMINATION ASSOCIATED WITH HOLE APPROX .250 INDIAMETER / REMOVED AND REPLACED PANEL 193B PER AMM 53-51-21