As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT THRESHOLD WEB INBD FLOOR STRAP AT STA 807+2' CORRODED AROUND NUTPLATE HOLE / REMOVED CORROSION AT AFT PIT THRESHOLD WEB STRAP AT STA 807+2 IAW SRM 51-10-02-0G-0. VERIFIED MATERIAL LIMITS. ORIG .100' LOSS .027' REMAINING .077'. FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A1. REMOVED AND REPLACED STRP STA 787-867 IAW B737-700 SRM 51-40-02-0G-0; 51-40-05-0G-0 & DWG 146A 8120 REV-