As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO PIT; STA 480+12-500A; R/H SIDE SHIELD ABOVE STR 26R; MULTIPLE AREAS OF BARE METAL / CORROSION / REMOVED CORROSION FROM R/H SIDE SHIELD ABOVE STR 26R IAW SRM 51-10-02-0G-0. VERIFIED REMOVAL W/10X MAGNIFING GLASS. ORG T=.040 REM T=.031 LOSS=.009 MAX ALLOWABLE LOSS=.004 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. INSTALLED NEW R/H SIDE SHIELD IAW SRM 51-40-02-0G-0 & B DWG 143A0080.