What was found
RT HORIZONTAL STAB LOWER IN-SPAR SKIN, CRACKED INBOARD OF RIB AT HSS 193.90, CRACK IS .200' LONG & 17.2' FROM FRONT SPAR. REMOVED DAMAGED SECTION IAW SRM 55-10-01-2R-11 PARA 4A; 4B(2) AND 4C. NO INITIAL REPAIR OR MULTIPLE SITE DAMAGE NOTED. HFEC INSPECTED CUTOUT AREA IAW NDTM PART 6 51-00-00 PROCEDURE 23; NO CRACKS NOTED. FABRICATED REPAIR. APPLIED CHEMICAL CONVERSION COATING TO REPAIR PARTS & SKIN AT REPAIR AREA IAW SRM 55-10-01-2R-11 PARA 4 G THROUGH 4M. PRIMED REPAIR & AREA IAW SRM 55-10-01-2R-11 PARA 4N. INSTALLED REPAIR IAW SRM 55-10-01-2R-11 PARA 4O & 4P.