What was found
CRACK FOUND AT LEFT HORIZONTAL STAB LOWER SKIN HSS 193.90, I/B ROW 9 CRACK :0.75'. CUT OUT DAMAGED AREA AT LT HORIZ. STAB. LOWER SKIN STA 193.90 (2 PLACES) 17' AND 24' FROM FWD EDGE PER B737-700 SRM 55-10-01-2R-11 FIG. 204. PERFORMED HFEC AT CUT OUT IAW NDTM PART 6; 51-00-00 PROCEDURE 23. NO CRACKS. PERFORMED HFEC HOLE PROBE INSPECTION ON ALL REMOVED FASTENER LOCATIONS WITHIN REPAIR AREA IAW NDTM PART 6; 51-00-00; PROCEDURE 16. NO CRACKS. FABRICATED FILLERS (2EA) IAW SRM 55-10-01-2R-11 FIG. 204. FABRICATION DOUBLER REPAIR IAW SRM 55-10-01-2R-11 FIG. 204