What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S. 727C+18; 727D+5; 727D+8; 727D+14; 727E+10; 727E+14; 727E+18; 747+6 AND 747+18; R.B.L. 22. / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT B.S.727C+18 THE LOWES REMAINING THICKNESS 0.032' MEASURES: L= 2.600' W= 0.900' D= 0.008' ORIGINAL MATERIAL THICKNESS= 0.040' FOUND TO BE OUT OF LIMITS I.A.W. SRM 53-00-53-1A-2 STEP 4 TOOL USED : ID: ATS 1672 S/N 650929 DUE : 03/2022;[02] VERIFIED CORRECTIVE ACTION 1. OUT OF LIMITS.<BR><BR>VERIFIED APPLICABILITY OF SRM 53-00-53-1A-2;[03] FABRICATED FLOOR TO SIDEWALL SUPPORT AT B.S. 727 AT 767 RBL22 FROM BAC1496-377#7075T62 LOT#1477704-1 IAW. SRM 51-40-05-0G-0 DWG NUMBER: 1467502 OK TREAT AND PRIMER;[04] VERIFIED CORRECTIVE ACTION 3.<BR><BR>OK TREAT AND PRIMER;[05] APPLIED ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS727 TO BS767 RBL22 CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01 AND SOPM 20-41-02;[06] VERIFIED CORRECTIVE ACTION ENTRY 5.;[07] OK TO INSTALL;[08] OK TO INSTALL;[09] INSTALLED NEW FLOOR TO SIDEWALL SUPPORT FROM BS727 TO BS767 RBL22 WL156 MAT. USED BAC1496-377#7075T62 LOT#1477704-1 IAW. SRM 51-40-02-0G-0 DWG:146A7500;[10] VERIFIED CORRECTIVE ACTION 9;[11] VERIFIED COMPLETE