What was found
AFT PIT DOOR CUT OUT LOWER SILL BEAM INBOARD CLIP UPPER FLANGE IS BUCKLED BS 860; RBL 18. / REMOVED CLIP FROM STA 860 RBL 18. RECIEVED NEW CLIP FROM BACKSHOP ON W/O 39151-1600-0002 P/N 146A8125-45. LOCATED AND DRILLED NEW CLIP IAW DWG 146A0081 REV AND SRM 51-40-05-0G-0. TREATED AND PRIMED AND ACCOMPLISHED CONFORMITY INSTALLED NEW CLIP IAW B737-700 SRM 51-40-02-0G-0 AND DWG 146A0081 REV C