What was found
FWD CARGO COMPARTMENT; BILGE AREA; STA 480 + 14 - 500A; ABOVE STR 26R; SHIELD HAS MULTIPLE AREAS OF CORROSION / REMOVED CORROSION IAW SRM 53-30-15-1A-1 100% MATERIAL LOSS FOUND TO BE OUT OF LIMITS. REMOVED SHEILD ABOVE STR 26R IAW SRM 51-40-02-0G-0. VERIFIED NEW PART 143A8126U31 IAW DWG 143A0080 SHEET 19 REV- ATAG# GM2088. LOCATED AND DRILLED NEW PART IAW SRM 51-40-05-0G-0 AND DWG 143A0080 SHEET 19 REV-. INSTALLED IAW SRM 51-40-02-0G-0 AND DWG 143A0080 SHEET 19 REV-