What was found
***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT RBL27 BS400-BS420 WL156 FCB / DAMAGE TO SIDEWALL SUPPORT FOUND TO BE OUT OF LIMITS PER SRM CH 53-00-53-1A-2. REMOVED AND REPLACED SUPPORT IAW SRM CH 51-40-02 AND DRAWING #143A7501.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT RBL27 BS400-BS420 WL156 FCB / DAMAGE TO SIDEWALL SUPPORT FOUND TO BE OUT OF LIMITS PER SRM CH 53-00-53-1A-2. REMOVED AND REPLACED SUPPORT IAW SRM CH 51-40-02 AND DRAWING #143A7501.