What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S. 727B+6; 727B+10; 727B+14; 727C+2; 727D+18; 727E+6; 727E+10; 727E+14; 747+6 AND 747+18; L.B.L. 22. / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT LBL 21 BETWEEN BS2727B+6 INCHES TO BS747+18 INCHE. THE LOWEST REMAINING THICKNESS. 32' ON BLENDED AREA L=2' W=1' D=.008 ORIG.MAT THK.=.040' FOUND TO BE OUT OF LIMITS I.A.W. SRM 53-00-53-1A-2 STEP 4A FIG. 103 DETAIL D.TOOL USED: ID: ATS 1225 S/.N UNKOWN DUE: 07/2022 FABRICATED ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT BS 727 TO BS 847 LBL22 FROM BAC1496-377#7075T62 LOT#1477704-1 IAW SRM 51-40-05; DGW146A7502 AND FABRICATED SPLICE SIDEPLATE BS 747+10 IAW SRM 53-00-53-2R-6 REPAIR 6;[06] OK TREAT AND PRIMER;[07] VERIFIED CORRECTIVE ACTION 6.<BR>OK TO TREAT AND PRIME;[08] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON AFT CARGO BAY FLOOR TO SIDEWALLL SUPPORT BS 727 TO BS 847 LBL22 AND SPLICE SIDEPLATE IAW SRM 51-20-01 AND SOPM 20-41-02. OK TO INSTALL SPLICE SIDEPLATE;[09] VERIFIED CORRECTIVE ACTION ENTRY 8<BR><BR>OK TO INSTALL SPLICE PLATE;[10] INSTALLED ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT SPLICE SIDEPLATE BS747+10 LBL 22 IAW SRM 53-00-53-2R-6 REPAIR 6;[11] VERIFIED CORRECTIVE ACTION ENTRY 10.;[12] OK TO INSTALL;[13] OK TO INSTALL;[14] INSTALLED ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT BS727 TO BS847 LBL 22 IAW SRM 51-40-02 AND DWG 146A7500;[15] VERIFIED CORRECTIVE ACTION 14;[16] VERIFIED COMPLETE;[17] UPDATED STEP 15 IN MEASURES TABLE.