What was found
PANEL 561CB HAS SEVERAL PULLED FASTENER HOLES (MARKED) / FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 57-51-01-1A-1; PARA. 4.B.(5). <BR><BR>DAMAGE WILL BE REPAIRED ACCORDING TO SRM 51-70-04-2R-9; AS REQUIRED BY SRM 57-51-01-2R-1; PARA. 4.B.(2); TABLE 202. <BR><BR>REMOVED FINISHES COMMON TO AFT EDGEBAND; COUNTERSUNK DAMAGED FASTENER HOLES TO REMOVE DAMAGE; TAP TESTED AREA - NO DISBONDS NOTED; CLEANED AND PREPARED REPAIR AREA ACCORDING TO SRM SRM 51-70-04-2R-9; PARA'S 4.A THRU 4.C.;[02] CHANGED DAMAGE DIMENSIONS.;[03] VALIDATED APPLICABILITY OF REPAIR TO BE COMPLETED IAW SRM 51-70-04-2R-9.;[04] VERIFIED CORRECTIVE ACTIONS 1-3<BR><BR>VALIDATED APPLICABILITY OF REPAIR TO BE COMPLETED IAW SRM 51-70-04-2R-9.SANDED RESIN/FIBER MIX FLUSH; CLEANED REPAIR AREA; APPLIED REPAIR PLIES FABRICATED FROM BMS 9-3; ST1581 FIBERGLASS (LOT# 1475360-2) AND BMS 8-301; CL1 RESIN (LOT# JH1KAA1767); VACUUM BAGGED REPAIR AREA FOR HEAT BLANKET CURE; AND ACCOMPLISHED SUCCESSFUL VACUUM BLEED DOWN TEST;CURED REPAIR; UNBAGGED; TRIMMED; LIGHTLY SANDED; AND CLEANED PER SRM 51-70-04 2R-9 PAR.4M.<BR><BR>REQUEST NDI INSPECTION.;[08] VERIFIED CORRECTIVE ACTIONS 5-7;[09] UT INSPECTED POST CURE IAW 737 NDTM PART 4 51-00-02; NO DISBONDS NOTED. <BR>EQUIP USED: EPOCH 650 ID: ATS2031;[10] REFINISHED PANEL IAW SRM 51-70-04-2R-9 PARA 4.P.