What was found
CORROSION ON FWD ENTRY DOOR THRESHOLD SUPPORT ANGLE BS335; BS321; LBL59 WL208. / [01] REMOVED CORROSION ON FWD ENTRY DOOR THRESHOLD SUPPORT ANGLE BS321 TO BS335 LBL59 WL 208 IAW SRM 51-10-02-0G-0; AND EVALUATED AREA AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1 PART 4.C(2) FIG.108 DETAIL D; MEASURES OF CORROSION L=5.0'' X W=1.0'' X D=0.025''; TOOL USED CALIPER ID:ATS2503 S/N: A19335646;[02] VERIFIED CORRECTIVE ACTION ITEM 1.;[03] REMOVED FWD ENTRY DOOR THRESHOLD SUPPORT ANGLE BS303.9 TO BS348.2 LBL59 WL 208 IAW SRM 51-40-02-0G-0;[04] VERIFIED APPLICABILITY SRM 53-10-15-0I-1 IDENTIFICATION 1; SRM 53-10-15-1A-1 ALLOWABLE DAMAGE 1 FOR SUPPORT ANGLE BS303.9 TO 348.2; LBL59; WL208.;[05] LOCATED AND DRILLED NEW SUPPORT ANGLE ITEM 141A8112-20; PO#786153 /1 LOC ON FWD ENTRY DOOR BTW BS303.9 TO 348.2; LBL59; WL208. IAW. SRM 51-40-05-0G-0.;[06] VERIFIED LOCATE AND DRILL OF THE FED THRESHOLD SUPPORT ANGLE PER SRM 51-40-05-0G-0.;[07] OK TO INSTALL NEW SUPPORT ANGLE ITEM 141A8112-20; PO#786153 /1 LOC ON FWD ENTRY DOOR BTW BS303.9 TO 348.2; LBL59; WL208;[08] VERIFIED OK TO INSTALL REPAIR PARTS.;[09] INSTALLED NEW SUPPORT ANGLE AT BS303.9 TO 348.2; LBL59; WL208IAW SRM 51-40-02 AND DWG 141A8110;[10] VERIFIED CORRECTIVE ACTION 9;[11] VERIFIED COMPLETE;[12] UPDATED MEASURES BLOCK 15; AND VARIOUS N/AS