What was found
CORROSION ON FLOOR SUPPORT AT FWD PASSENGER CABIN BS305; BS308 LBL11 WL208. / [01] EVALUATED INTERCOSTAL FLOOR SUPPORT AT FWD PASSENGER CABIN BS305-308 LBL11 WL208 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1 PART 1.B(4). PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0.;[02] VERIFIED CORRECTIVE ACTION 1. PART TO BE REPLACED.;[03] REMOVED INTERCOSTAL FLOOR SUPPORT AT BS294.5 - BS312; LBL11; WL208 IAW SRM 51-40-02;[04] LOCATED AND DRILLED NEW INTERCOSTAL FLOOR SUPPORT P/N: 141A5690U1; LOT: 1481783-4; AT BS294.5 - BS312; LBL11; WL208 IAW SRM 51-40-05.;[05] VERIFIED CORRECTIVE ACTION 3 AND 4.;[06] INSTALLED NEW INTERCOSTAL FLOOR SUPPORT P/N: 141A5690U1; LOT: 1481783-4; AT BS294.5 - BS312; LBL11; WL208 IAW SRM 51-40-02 AND DWG 141A5600;[07] VERIFIED CORRECTIVE ACTION 6;[08] COMPLETED ALL MAINTENANCE ACTIONS;[09] VERIFIED COMPLETE;[10] UPDATED N/A AND STEP 15 ON MEASURES BLOCK.