What was found
FWD LAV AFT OUTBD FLOOR MOUNT FITTING HAS EVIDENCE OF CORROSION INSIDE MOUNT BOLT HOLE / REMOVED AND REPLACED INTERCOSTAL AT F.S 294.5 TO F.S 312 LBL 45 PER SRM 51-40-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD LAV AFT OUTBD FLOOR MOUNT FITTING HAS EVIDENCE OF CORROSION INSIDE MOUNT BOLT HOLE / REMOVED AND REPLACED INTERCOSTAL AT F.S 294.5 TO F.S 312 LBL 45 PER SRM 51-40-02