What was found
AFT CARGO PIT FLOOR BEAM STA 727+4 LBL13 HAS EVIDENCE OF CORROSION EMITTING FROM MATING SURFACE / REMOVED DAMAGE IAW SRM 51-10-02; VERIFIED LIMITS ORG 'T' .090' LOSS .050' REMAINING .040' OUT OF LIMITS IAW SRM 53-00-53-1A-2 DETAIL C; REMOVED FASTENERS FOR ACCESS AND REMOVED FLOOR SUPPORT IAW SRM 51-40-02-0G-0; VERIFIED MATERIAL P/N AND 10136-2007 7075 T6 IAW DWG 144A2616 REV. C PRIMED PART IAW SRM 51-20-01-0G-0 INSTALLED NEW PART IAW SRM 51-40-02-0G-0 APPLIED CIC AREA REWORK IAW SRM 51-20-01-0G-0 P/N 144A2616-7