What was found
RT MLG FWD TRUNNION LOCATION #2 UPPER I/B INNER FACE SHOWS EVIDENCE OF CORROSION. DOT 82-059. / AT RIGHT MLG FWD TRUNNION FITTING LOCATION #2 UPPER I/B INNER FACE; SPOT-FACED INNER SURFACE DEPTH OF A 0.36' AND DIAMETER OF THE 2.750' NO SIGN OF CORROSION REMAIN PER B737-700 SRM 57-20-90-2R-2. INSTALLED SERVICABLE BUSHINGS AT RIGHT MLG FWD TRUNNION FITTING AS PER B737-700 SOPM 20-50-03; RIGHT MLG TRUNNION BEARING ASSY TO BE INSTALLED ON CUSTOMER CARD 732-11-01 POS2.