As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT MLG FWD TRUNNION LOCATION #1 UPPER O/B INNER FACE SHOWS EVIDENCE OF CORROSION. DOT 82-065. / AT LEFT MLG FWD TRUNNION FITTING LOCATION #1 UPPER O/B INNER FACE SPOT FACE ARE DEPTH OF 0.032' AND DIAMETER OF 2.750' NO SIGN OF CORROSION REMAIN PER B737-700 SRM 57-20-90-2R-2 INSTALLED SERVICABLE BUSHINGS AT LEFT MLG FWD TRUNNION FITTING #1 O/B UPPER PER B737-700 SOPM 20-50-03.