What was found
CABIN FLOOR PANEL SUPPORT ANGLE AT STA. 540 IS CRACKED AT FASTNER HOLE AT RBL 44. MRKD / INSTALLED CABIN FLOOR PANEL SUPPORT ANGLE AT STA 540 RBL 44 IAW SRM 51-40-02. SEE INDIVIDUAL SIGN-OFF FOR WORK ACCOMPLISHED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR PANEL SUPPORT ANGLE AT STA. 540 IS CRACKED AT FASTNER HOLE AT RBL 44. MRKD / INSTALLED CABIN FLOOR PANEL SUPPORT ANGLE AT STA 540 RBL 44 IAW SRM 51-40-02. SEE INDIVIDUAL SIGN-OFF FOR WORK ACCOMPLISHED.