What was found
CORROSION FLOOR STRUCTURE INTERCOSTAL-SEAL AT BST 1016 MORE 6 INCH; WL 208.1 AT LEVEL STR 17 RH AND BETWEEN RBL 16 TO RBL 26 AT PASSENGER CABIN 2022-55867 / [01] REPLACED INTERCOSTAL-SEAL AT BST 1016 MORE 6 INCH; WL 208.1 AT LEVEL STR 17 RH AND BETWEEN RBL 16 TO RBL 26 AT PASSENGER CABIN IAW B737-700 SRM 5-<BR>51-40-02; SRM 51-10-02 AND DWG 148A0922 SHEET 11 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[02] CORRECTED STEP 1<BR>REPLACED INTERCOSTAL-SEAL AT BST 1016 MORE 6 INCH; WL 208.1 AT LEVEL STR 17 RH AND BETWEEN RBL 16 TO RBL 26 AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; SRM 51-10-02 AND DWG 148A0922 SHEET 11 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[03] TASK COMPLETED ; RII <BR>SEE INDIVIDUAL SIGN OFF BELOW