What was found
CORROSION FLOOR STRUCTURE INTERCOSTAL SEAL AT BST 1016 MORE 6 INCH WL 208.1 AT LEVER STR 17LH AND BETWEEN LBL 16 TO LBL 26 AT PASSENGER CABIN 2022-55873 / [01] REPLACED INTERCOSTAL SEAL FLOOR STRUCTURE AT BST 1016 MORE 6 INCH WL 208.1 AT LEVER STR 17LH AND BETWEEN LBL 16 TO LBL 26 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 PARAGRAPH 9;SRM 51-40-02 AND DWG 148A0922 SHEET 11 REV - . SEE INDIVIDUAL SIGN OFFS BELLOW .;[02] REPLACED INTERCOSTAL SEAL FLOOR STRUCTURE AT BST 1016 MORE 6 INCH WL 208.1 AT LEVER STR 17LH AND BETWEEN LBL 16 TO LBL 26 AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 PARAGRAPH 9;SRM 51-40-02 AND DWG 148A0922 SHEET 11 REV - . SEE INDIVIDUAL SIGN OFFS BELLOW . AS RII