What was found
TAIL COMPARTMENT STATION 1088 BULKHEAD; APU TRANSITION DUCT ATTACH POINT; LOWER SURFACE FORWARD SIDE HAS AREAS OF CORROSION AT RBL 24' AND W L 226 / EVALUATED CORRODED ATTACH STRIP/BRACKET IN TAIL COMPT STA 1088 AT RBL 24' AND WL 226 LWR SURFACE FWD SIDE. NO ALLOWABLE LIMITS FOUND IN SRM-MORE THAN 50% MATERIAL LOSS-OUT OF LIMITS. REMOVED CORRODED STRIP/BRACKET AT APU TRASITION DUCT LWR ATTACH POINT. INSTALLED NEW STRIP/BRACKET. I.A.W. SRM 51-40-02-0G-0; DWG# 148A0924 REV.-