What was found
CRACK ANGLE LOCATED BS695 AND BL0 TO RBL1 AT CENTER WING BOX 2022-94819 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 02-FEB-23; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; SN: 142811019; DUE DATE: 02-FRB-23;;[02] REPLACED ANGLE LOCATED BS695 AND BL0 TO RBL1 AT CENTER WING BOX IAW SRM B737-700 51-40-02 Ï¿½TEM 9 AND DRAWING 273A9110; SHEET 5; REV: A; SEE INDIVIDUAL SIGNOFFS BELOW.;[03] CERTIFIED RII WORK PERFORMED. <BR>SEE INDIVIDUAL SIGNOFFS BELOW.