What was found
ATTACHING ANGLE FOR THE PRESSURE SEAL AT STA 1016 LH BL-2 IS CRACKED / REMOVED CRACKED ANGLE FROM BS 1016 RH BL-2 IAW SRM 51-40-02-0G-0 VERIFIED MATERIAL .020' 7075+6 IAW DWG 65-54862 FABRICATED ANGLE IAW SRM 51-40-05-0G-0 AND DWG 148A0922 REV. A TREATED AND PRIMER PART IAW SRM 51-20-01-0G-0 AND AMM 51-21-72-370-801 ACCOMPLISHED COMFIRMITY INSPECTION AND VERIFIED ATTACH ANGLE P/N 65-54862-20 CONFORMS TO THE SPECIFICATION FOUND IN BOEING DWG 148A0922 REV. A INSTALLED NEW PART AT BS 1016 RH BL-2 IAW SRM 51-40-02-0G-0 AND DWG 148A0922 REV. A APPLIED CIC TO AREA REWORK IAW AMM 51-21-91-620-802