What was found
***CORROSION*** ***CORROSION*** IN MULTIPLE LOCATIONS ON ACB FLOOR TRACK STA 887-927 LBL 3 WL WL 175 (MARKED) / REMOVED CORROSION IN MULTIPLE 1' X 2' LOCATIONS ON ACB FLOOR TRACK STA 887-927; LBL3; WL175; ORIGINAL THICKNESS .070; REMAINING THICKNESS .060; MATERIAL REMOVED .010; FOUND OUT OF SRM ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED ACB FLOOR TRAC STA 847-947; LBL 3; WL175 IAW SRM 51-40-02-0G-0 AND DWG 147A7500