What was found
CORROSION ON FORWARD SERVICE DOOR MOP SILL AT B.S. 328+12; R.B.L. 60. / [01] SRM 53-10-15-0I-2 FOR IDENTIFICATION AND SRM 53-10-15-1A-2 FOR ALLOWABLE DAMAGE ARE APPLICABLE;[02] REMOVED CORROSION AT DISCREPANCY AREA;FOUND OUT OF LIMIT; THE MATERIAL REMOVED EXCEEDS LIMITS PER SRM 53-10-15-1A-2 FIGURE 103 DETAIL G. TOOL USED: <BR>ID: ATS1672 <BR>S/N: 65092939 <BR>DUE: 03/2022;[03] VERIFIED CORRECTIVE ACTION ENTRIES 1. AND 2<BR><BR>INNER CORD;[04] REMOVED FWD SERVICE DOOR MOP SILL FROM BS-259.5 TO BS-360; RBL 60; PER SRM 51-40-02-0G-0;[05] LOCATED ; DRILLED AND INSTALLED ACOMMPLISHED ON CUSTOMER CARD TTG8Q00ASFE7; 7275 INTERIOR 5063 NO FOUTHER ACTION REQUIRE JOB COMPLETED;[06] LOCATED ; DRILLED AND INSTALLED ACOMMPLISHED ON CUSTOMER CARD TTG8Q00ASF59; NO FOUTHER ACTION REQUIRE JOB COMPLETED;[07] ALL STEP COMPLETED;[08] PART USAGE INFO;[09] VERIFIED CORRECTIVE ACTION STEP 6.