As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR PANEL 241ABF HAS DAMAGED INSERTS. / [01] REMOVED 22EA. THRU INSERTS; AND 4EA. BLIND INSERTS; ALL ACCORDING TO SRM 53-00-50-2R-0; PARA. 2.B.(2).;[02] DUE TO THE EXTENT OF DAMAGE; REPLACED FLOOR PANEL 241ABF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-26 ITEM 156.;[03] PANEL REPLACED. JOB COMPLETE.