What was found
CORROSION ON AFT BULKHEAD TO SIDEWALL SUPPORT ANGLE AT FWD CARGO BAY BS500D LBL25. MARKED. / [01] REMOVED CORROSION ON SUPPORT ANGLE IN A AREA OH 1' X 1' REMAINING THICKNESS IS LESS THEN 0.056' FOUND TO BE OUT OF LIMITS PER SRM 53-30-08-1A-1.;[02] VERIFIED CORRECTIVE ACTION 1;[03] LOCATED AND DRILLED NEW BULKHEAD TO SIDEWALL SUPPORT ANGLE AT BS 500D BTW S-18L -S-26L IAW SRM 51-40-05-0G-0 AND DWG 143A9481.;[04] INSPECTED ACTION 3;[05] ALL WORK COMPLETE;[06] UPDATED PART USE;[07] VERIFIED