What was found
CRACKED FLOOR SUPPORT BS 270-294 BL 0 WL 208 / [01] REMOVED CRACKED FLOOR SUPPORT AT BS 270-294 BL 0 WL 208 AND LOCATED AND DRILLED NEW FLOOR SUPPORT PER SRM 51-40-02 AND SRM 51-40-05. DRW 141A5400. REQUEST OK TO INSTALL.;[02] INSPECTED AND VERIFIED ACTION 1; OK TO INSTALL;[03] STEP 1 APPLICABILITY STATEMENT;[04] STEP 1 COMPLETE;[05] INSTALLED NEW FLOOR SUPPORT AT BS 270-294 BL 0 WL 208 PER SRM 51-40-02 AND SRM 51-40-05. DRW 141A5400.;[06] RII INSPECTED ACTION 5;[07] INSPECTION COMPLETE