What was found
P18 ATTACH CLIP BROKEN BS261 STRINGER 8LT / [01] REMOVED ATTACH CLIP AT BS 261 STRINGER 8LT IAW SRM 51-40-02;[02] STEP 1 COMPLETE;[03] PARTIAL UPDATE STEP 2.;[04] PARTIAL UPDATE STEP 3.;[05] LOCATED AND DRILLED NEW P18 ATTACH CLIP PER SRM 51-40-05 AND DWG#141A9502. OK TO INSTALL.;[06] VERIFIED PARTIAL STEPS 2 AND 3. VERIFIED CORRECTIVE ACTION STEP 5. VERIFIED OK TO INSTALL.;[07] INSTALLED NEW P18 ATTACH CLIP AT BS 261 STRINGER 8LT PER SRM 51-40-02 AND DWG#141A0720.;[08] VERIFIED CORRECTIVE ACTION #7