What was found
CORROSION ON INTERCOSTAL SUPPORT ANGLE AT B.S. 312+4 - 312 + 12 STRINGER 23 LEFT IN MAIN EBAY. / REMOVED DAMAGE AT ALL LOCATIONS BS 312+4 IN AN AREA OF 2.5' X 1'AND BS 312+12' IN AN AREA OF 0.8'X 0.5' PER SRM 51-10-02-0G-0;[03] VERIFIED CORRECTIVE ACTION 2.;[04] VERIFIED APPLICABILITY OF SRM 53-10-15-1A-1 CORROSION NOTED IN BLEND AREA AT BS 312 + 12'. JOB STEP CREATED TO REMOVE ALL CORROSION.;[20] COMPLETED STEP 1;[21] CORRECTION: CORRECTIVE ACTION 16; DIMENSIONS AT BS 312+4' IS 2.1' X 0.9' AND BS 312+ 12 IS 1.1 X 0.9'';[22] VERIFIED CORRECTIVE ACTION 1 AND 16.;[23] REQUEST UT FOR REMAINING THICKNESS AT BS 312+12';[24] VERIFIED STEP 1.;[25] CORRECTIVE ACTION 18 WRITTEN IN ERROR;[26] UT INSPECTED BLENDED AREA AT BS 312+12' IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2; REMAINING THICKNESS IS 0.077' ADJACENT TO 0.1'. SEE ATTACHED GRID<BR>EQUIP USED: EPOCH 650 ID: ATS2031;[27] UPDATED MEASUREMENTS.;[28] RECEIVED CLIP ON SWA RO # 857532-SWA. SHOT PEEN THE MACHINED SURFACES PER SOPM 20-10-03 USING POST MACHINING THICKNESS AND APPLIED CHEMICAL CONVERSION COATING TO NEW CLIP PER SWA EA 22-153-00398.INSTALLED 100% TEMPORARY AND PERMANENT FASTENERS AT REPAIR PARTS IAW SWA EA 22-153-00398 AND SRM 51-40-02-0G-0 BEFORE SQUEEZE OUT TIME EXPIRE SEALANT USED BMS 5-95 C-20 APPLIED AT 23-FEB-2022 20:30 UTC INSTALLED REPAIR PARTS IAW SWA EA 22-153-00398 AND SRM 51-40-02-0G-0.;[33] INSTALLED REPAIR PARTS IAW SWA EA 22-153-00398 WIP 1 AND SRM 51-40-02-0G-0.] REPAIRED INTERCOSTAL PER EA 22-153-00398