What was found
FLOOR SUPPORT CRACKED BS 312-328 LBL45 WL 208 / REMOVED AND LOCATED NEW FLOOR SUPPORT AT BS 312 - 328; LBL 45; WL 208 IAW SRM 51-40-02-0G-0 0G-0 AND DWG # 141A5400. DRILLED NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0 AND DWG # 141A5400. OK TO INSTALL. 92978U 22SEP19 LEAD 281 22SEP19 INSP 28 22SEP19. INSTALLED NEW FLOOR SUPPORT AT B.S. 312 - 328; LBL 45; WL 208. IAW SRM 51-40-02-0G-0 AND DWG # 141A5400. 92978U 22SEP19