What was found
#2 ENG. AFT STRUT FAIRING. AFT FITTING IS CRACKED / COMPLIED WITH WORK INSTRUCTION NO. REPAIR-54EA-07244. GENERAL VISUAL INSPECTION MUST BE PERFORMED AT THE END OF CRACK FOR ANY PROGRESSION EVERY 8 DAYS (NOTE PANEL #444BR MUST BE REMOVED TO PERFORM STOP DRILL GVI) PERMANENT REPAIR MUST BE COMPLIED WITH WITHIN 60 DAYS CONSISTING OF REPAIR OR REPLACEMENT OF; CRACKED AFT TRAILING EDGE ASSY (P/N 313A2752-1) OR REPLACEMENT PANEL (P/N313A2752-2) AMT 59828INSP 26613