What was found
AFT CARGO COMP STA 947.5 FLOOR SUPPORT ANGLE CORRODED BETWEEN LBL 11' AND RBL 20' / [01] REMOVED CORROSION FROM AFT CARGO COMPARTMENT STA 947.5 FLOOR SUPPORT ANGLE IAW B 737-700 SRM 51-10-02-0G-0.;;[13] (FINAL) REMOVED CORROSION FROM AFT CARGO COMPARTMENT STA 947.5 FLOOR SUPPORT ANGLE IAW B 737-700 SRM 51-10-02-0G-0. EVALUATED AREA: ORIGINAL THICKNESS IS 0.080'. MATERIAL REMOVED IS 0.014'. MATERIAL REMAINING 0.066' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; FIG. 103; A-A. LOCATED; DRILLED; AND INSTALLED NEW AFT CARGO COMPARTMENT STA 947.5 FLOOR SUPPORT ANGLE IAW SRM 51-40-02-0G-0 AND SRM 51-40-05-0G-0.;[14] VERIFIED STEP #12;[15] FINAL INSPECTION; REPLACED FLOOR SUPPORT ANGLE.