What was found
LOWER FUSELAGE L/H WHEEL WELL VAPOR BARRIER LBL 35' AND 9' FROM BOTTOM PREVIOUS REPAIR SEALANT DISBONDING / [01] PREPARED DAMAGEAREA FOR DRY-OUT AT VAPOR BARRIER B737-700 51-70-2R-0;[02] VERIFIED STEP #1.;[03] PERFORMED DRY OUT ON L/H VAPOR BARRIER AS PER B737 SRM 51-70-04-2R-10;[04] CORRECTING REF ON STEP 1: PREPARED DAMAGE AREA FOR DRY-OUT AT VAPOR BARRIER PER REF B737-700 SRM 51-70-04-2R-0;[05] VERIFIED 2-3. OK TO INSTALL REPAIR.;[06] VERIFIED STEP #4.;[07] REPAIRED CRACK DAMAGE SIZE 15' ON L/H VAPOR BARRIER LBL. 35' AS PER B737-700 SRM 51-70-04-2R-10 MATERIALS USED PO# 1746221 AND PO# 1690463;[08] VERIFIED STEP #7; CRACKED REPAIRED.;[09] RESTORED FINISHED ON REPAIR AREA PER REF B737 AMM 51-21-73-370-803;[10] REPAIRED CRACK DAMAGE SIZE 15' ON L/H VAPOR BARRIER LBL. 35' AS PER B737-700 SRM 51-70-04-2R-10;[11] STEP #8 CHANGE TO (RII) VERIFIED STEP #7; CRACKED REPAIRED.;[12] NOTE: (RII) FINAL INSPECTION; VERIFIED STEPS #9 AND #10.