What was found
CORROSION - FOUND CORROSION ON WASTE SYSTEM SERVICE DOOR AT BONDING JUMPER ATTACHMENT / REMOVED CORROSION ON WASTE SYSTEM SERVICE DOOR AT BONDING JUMPER AS PER B737-700 SRM 51-10-02-0G-0; FOUND TO BE OUT OF LIMITS AS PER B737-700 SRM; ORIG MAT : .060' ; MAT REMAINING : .044'; AS PER B-737-700 ; SRM 52-40-01-4 . REMOVED AND REPLACED WASTE SYSTEM SERVICE DOOR AS PER B737-700 ; SWA - SRM 51-10-00-0G-0 AND SWPM ; 52-49-09-000-801 .