What was found
CRACK WEB LOCATED ON FLOOR STRUCTURE BTW BS 328 TO BS 344 AT LBL 45 AT FWD GALLEY AREA 2022-80131 / [01] REPLACED WEB AND FASTENERS LOCATED ON FLOOR STRUCTURE BTW BS 328 TO BS 344 AT LBL 45 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 ITEM 9 AND DWG 141A5400 REV -. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED WEB AND FASTENERS LOCATED ON FLOOR STRUCTURE BTW BS 328 TO BS 344 AT LBL 45 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 ITEM 9 AND DWG 141A5400 REV -. SEE INDIVIDUAL SIGN OFF BELOW. AS RII