What was found
CORROSION FLOOR BEAM LOCATED ON BS 294.5 AT RBL 11 AND WL 208.1 AT FWD GALLEY AREA 2022-80133 / [01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N: 210138503 DUE DATE: 05-MAR-22;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 02-FEB-23; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 02-FEB-23.;[03] TOOL USED PN: FPK-PRO-104; SN: PRO-3448; DUE DATE: 18-NOV-22;[04] REPAIRED FLOOR BEAM LOCATED ON BS 294.5 AT RBL 11 AND WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-16 REPAIR 16 ALTERNATIVE 1 AND DWG 141A5502 SHEET 15 REV-.;[05] REPAIRED FLOOR BEAM LOCATED ON BS 294.5 AT RBL 11 AND WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-16 REPAIR 16 ALTERNATIVE 1 AND DWG 141A5502 SHEET 15 REV-.